Overview
KERN ABT 120-5DNM analytical balances with 42 g; 120 g weighing capacity and 0.00001 g; 0.0001 g readability. Single-Cell weighing technology and 10 s; 4 s stabilisation support fast, precise and dependable measurements. Features include automatic internal adjustment, a glass draught shield, recipe weighing, LCD display and RS-232 standard connectivity. The premium model with single-cell weighing system. This guide brings together the performance data, operating functions and purchasing considerations a buyer should review when selecting the KERN ABT 120-5DNM. It is intended for organisations that value reliable measurements, straightforward operation, traceable processes and equipment suited to sustained use.
Performance and specification
The KERN ABT 120-5DNM is specified with maximum capacity of 42 g; 120 g, readability of 0.00001 g; 0.0001 g, repeatability of 0.00002 g; 0.0001 g, linearity of ± 0.00003 g; 0.0002 g, 10 s; 4 s stabilisation time. Its Single-Cell weighing system supports stable and dependable results. These figures help purchasers assess whether the model offers the right balance of capacity, resolution, speed and control for the items they intend to measure. Readability describes the smallest displayed increment, while repeatability and linearity indicate consistency across repeated readings and the operating range. Buyers should assess these values together rather than choosing on capacity alone. For piece counting, the stated smallest part weight is 1 mg under laboratory conditions and 10 mg under normal conditions. Correct installation, sensible environmental control and routine checking remain important for achieving the best performance.
Product features and everyday operation
Automatic internal adjustment in the case of a change in temperature ≥ 0.5 °C or timecontrolled every 4 h, guarantees high degree of accuracy and makes the balance independent of its location of use. Dosage aid: High stability mode and other filter settings can be selected. Simple recipe weighing and documenting with a combined tare/print function. In addition, the ingredients for the recipe are numbered automatically and printed out with their corresponding number and nominal weight. Identification number: 4 digits, printed on calibration protocol freely programmable. Printout of a GLP-compliant calibration report conveniently at the touch of a button. Automatic data output to the PC/printer each time the balance is steady. Large glass draught shield with 3 sliding doors for easy access to the items being weighed. Protective working cover included with delivery. These functions are intended to improve workflow as well as measurement quality. Operators can match the instrument to the task, reduce unnecessary manual steps and create consistent procedures. Where a function supports data output, user control, formulation, counting, tolerance checking or another specialist process, organisations should document its use within their standard operating procedures.
Display, construction and connectivity
The physical and operating specification includes metal housing, 215×340×335 mm overall dimensions, stainless steel weighing plate, 80 mm weighing surface, LCD display, 14 mm digit height, weighing units g; ct, Power supply unit power supply, interfaces including RS-232 standard. These details matter when planning space, positioning the instrument, connecting existing equipment and ensuring readings remain clear. Buyers should confirm available space, power requirements and interface compatibility before installation. The available RS-232 standard connectivity can support transfer of readings to compatible computers, printers or systems, depending on the selected workflow and software. Digital transfer can reduce transcription and help create timely records. The final process should be configured and validated by the user organisation where regulated or quality-controlled records are required.
Applications and purchasing considerations
The manufacturer identifies relevant application areas including professional laboratory, education, quality control and industrial duties where its specification is appropriate. Suitability depends on the required capacity, readability, accuracy, sample characteristics, environment and any legal or quality requirements. Buyers should also consider cleaning, operator access, documentation, data transfer and frequency of use. A model with the correct specification can improve efficiency and reduce avoidable rework, but it should be selected as part of the complete measuring process. Consider the work surface, vibration, draughts, temperature changes, electrostatic effects, sample handling and operator training. Routine checks and clear procedures help protect measurement quality over the instrument’s working life.
Ordering and compliance information
Multi-range balance, with increasing load it switches automatically to the next largest weighing range [Max] and readout [d] and when the load is fully removed, the balance switches back to the lower range. Purchasers should confirm any conformity assessment, verification or calibration requirement before ordering because some services must be completed before delivery or depend on the final installation location.
Additional product note
The USP minimum sample weight is a measure for the smallest permitted weight in accordance with USP (United States Pharmacopeia). This information should be considered alongside the organisation’s own procedures and applicable standards.
KERN brand story – professional measuring since 1844
KERN & SOHN is a family-owned German measurement specialist with a precision-measuring heritage dating to 1844. Headquartered in Balingen in southern Germany and developed across eight generations, KERN combines more than 180 years of experience with modern weighing technology, measuring instruments, software and professional services. The company supplies users in more than 90 countries across laboratory, industrial, medical, research, education and commercial applications. KERN’s history is rooted in precision balances and a continuing commitment to improving measurement instruments. Its portfolio includes weighing technology, test weights, optical instruments, measuring equipment and supporting software. KERN also operates a DAkkS-accredited calibration laboratory in accordance with DIN EN ISO/IEC 17025 and maintains an ISO 9001-certified quality management system. This combination of engineering heritage and accredited services gives customers access to professional equipment and ongoing metrological support.
Why Glana partnered with KERN
Glana partnered with KERN because professional customers need more than an impressive specification. They need dependable instruments, durable engineering, clear technical information and access to recognised calibration and conformity services. KERN’s focus on precision, stable results, intuitive operation, traceable records and connected workflows aligns with Glana’s commitment to helping customers choose equipment that supports accurate work and long-term operational value. The partnership enables Glana to guide customers through decisions including capacity, readability, accuracy, intended use, verification and calibration. Combining KERN’s manufacturing experience with Glana’s customer-focused support helps organisations select equipment that matches technical requirements and everyday practice.
Order the KERN ABT 120-5DNM from Glana
Choose the KERN ABT 120-5DNM for professional performance backed by KERN’s measurement heritage and Glana’s purchasing support. Contact Glana today for pricing and availability, to discuss calibration or conformity requirements, and to receive expert help confirming whether the ABT 120-5DNM is right for your application.
Practical purchasing guidance
Selection should be based on the complete application rather than a single headline figure. Compare expected minimum and maximum load, required resolution, acceptable uncertainty, environment and documentation needs. This helps ensure the chosen instrument remains useful as workloads develop and prevents a mismatch between nominal specification and daily practice.
For best results, position the instrument carefully, allow it to reach normal operating conditions and ensure it is used by trained personnel. Handle samples consistently and record routine checks at intervals appropriate to the quality system. Good measurement practice protects the equipment investment and the decisions made from its readings.
Purchasing guidance
Glana can help buyers review accessories, calibration options, data connections and installation considerations before purchase. Discussing these points early can simplify commissioning and help the equipment fit existing procedures from the first day. It also creates a clear basis for training, maintenance planning and future support.
| Size | COMPLETE WITH DAkkS CALIBRATION, PRODUCT ONLY |
|---|---|
| Range | KERN ANALYTICAL BALANCES |